For each different material multiply the thickness by the standard r value per inch for that material.
Roof insulation r value thickness.
None of the available insulating materials will fit within the depth of a 90 mm rafter but by selecting a 140 mm deep rafter it is possible to fit a wider choice of products including r values that exceed the minimum see figure 2.
Hunter panels roofing tech topic r105.
To calculate the total r value of a roof assembly find the total thickness in inches of each type of insulating material within the system.
Insulation level are specified by r value.
This exception will allow the minimum thickness to be 4 2 at the low point or 5 2 4 away from the drain on a per foot tapered system.
To compare different insulation products researchers have to create the exact same conditions and then measure how well the insulation performs.
There is an exception provided that allows the minimum thickness to be up to 1 less than the prescriptive r value at per foot slope as long as the system r value meets or exceeds that prescriptive r value.
But what does that mean and how do researchers determine r value.
R value is a measure of insulation s ability to resist heat traveling through it.
The higher the r value the better the thermal performance of the insulation.
Recommended home insulation r values.
Excellent lttr value compared to any other fm class 1 rated products of equivalent thickness.
The table below shows what levels of insulation are cost effective for different climates and.
Add the results for all the materials together to get the total r value for the roof assembly.
Firestone isogard polyiso insulation goes even further and was the first product on the market to meet both astm c1289 required and recommended thermal performance values.
Fm approved subject to the conditions of approval as a roof insulation when installed as shown in the current edition of the factory mutual research approvals guide.
To achieve a construction r value of 3 3 using the branz house insulation guide see page 35 rafters and dwangs an insulating material of r3 4 will be required.
Typical recommendations for exterior walls are r 13 to r 23 while r 30 r 38 and r 49 are common for ceilings and attic spaces.
At one inch thickness enerfoil tm achieves a 6 2 r value or a 1 08 rsi.
For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed in your attic to reach r 30 if you live in zones 2 or 3.
Zone 6 requires an r 30 minimum which is 5 2 thick.
Note from this chart that the ideal r value differs for each part of your home.
Firestone iso 95 gl polyiso insulation has a higher r value than other insulation products while also outperforming competitive polyiso at low temperature.