Load types loads used in design load equations are given letters by type.
Roof live load tables.
The reduction factors r 1 and r 2 shall be determined as follows.
For example in the rafter span table below the highlighted cell in the 40 live load table indicates that 2 x 8 southern yellow pine joists that have a grade of 2 that are spaced 24 apart can have a maximum span of 10 feet 3 inches 10 3 if designing for a live load of 40 lbs ft 2.
Notes to table 1607 1 for si.
Used but they typically defined the load cases or combination stress or strength limits and deflection limits.
D dead load l live load l r live roof load w wind load s snow load e earthquake load r rainwater load or ice water load.
Uniform live loads at roofs are permitted to be reduced in accordance with section 1607 12 2.
Floors in garages or portions of buildings used for the storage of motor vehicles shall be designed for the uniformly distributed live loads of table 1607 1 or the following concentrated loads.
This information is found in the code book.
1 for garages.
You must determine the snow load for your region.
If your code book says your snow load is 40 psf then you use the 40 psf live load rafter table.
For roof live loads of 12 psf or 16 psf table multiply tabulated multiply required number span by e value by 12 psf 16 psf 12 psf 16 psf.
The fact that snow loads only act part of the year has been used to create the rafter tables.
Equation 16 27 equation 16 28.
The snow load is treated as a live load when you use awc s tables.
The fact that snow loads only act part of the year has been used to create the rafter tables.
For roof live loads less than 20 pounds per square foot psf rafter spans and required e values tabulated for 20 psf shall be permitted to be adjusted in accordance with the fol lowing table.
This information is found in the code book.
If your code book says your snow load is 40 psf then you use the 40 psf live load rafter table.
L r reduced roof live load per square foot m 2 of horizontal projection supported by the member.
Except for uni form live loads at roofs all other minimum uniformly distrib uted live loads lo in table 1607 1 are permitted to be reduced in accordance with section 1607 10 1 or 1607 10 2.
Compression perpendicular to the grain.
1 inch 25 4 mm 1 square inch 645 16 mm 2 1 pound per square foot 0 0479 kn m 2 1 pound 0 004448 kn 1 pound per cubic foot 16 kg m 3.
Loads should be determined in accordance with this chapter.
Roof live loads largest roof loads typically caused by repair and maintenance pitch rise span lr 20 r1r2 12 lr 20 lr horizontal projection roof live load 16 r 1 r 2 live load reduction factors r 1 accounts for size of tributary area of roof column a t r 2 effect of the roof rise.
1607 10 1 basic uniform live load reduction.
The snow load is treated as a live load when you use af pa s tables.